Honeywell 107324A User Manual

Browse online or download User Manual for Computer liquid cooling Honeywell 107324A. Honeywell 107324A User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
PRODUCT DATA
68-0040-04
Immersion Wells and Compression Fittings
FOR TEMPERATURE CONTROLLERS
APPLICATION
Immersion wells, compression fittings and element holders
are used with Aquastat® Temperature Controllers to hold the
temperature sensing bulb in the controlled medium.
Immersion wells and compression fittings also prevent
leakage of the controlled medium.
FEATURES
Immersion wells and compression fittings are
available to fit a 1/2-14 or 3/4-14 NPT tapping with
a range of insulation depths.
Immersion wells and compression fittings are
available in a variety of lengths and diameters.
Immersion wells and compression fittings are
available in a variety of materials, to suit the
application. Materials include: brass, copper,
stainless steel, mild steel or Monel.
Element holders support the capillary and bulb
or an averaging element in duct applications.
Bulb shields protect the sensing bulb from sun
and weather with the bulb installed outdoors.
Accessories, including mounting clips, heat-
conductive compound, waste nuts, a pipe strap
and a well adapter, are available for mounting
sensing bulbs in various applications.
Immersion wells allow heat transfer while
protecting the sensing bulb from contact with the
controlled medium.
Immersion wells permit removal of the sensing
bulb for testing or replacement without draining
the system.
Compression fittings seal the boiler and allow
bulb insertion directly into the controlled
medium.
IMMERSION WELL
112632AA
IMMERSION WELL
107324A
ELEMENT
HOLDER
104484A
COMPRESSION FITTING
121371B
Contents
Application ........................................................................ 1
Features ........................................................................... 1
Specifications ................................................................... 2
Ordering Information ........................................................ 2
General Information .......................................................... 7
Installation ........................................................................ 8
Checkout .......................................................................... 13
Cross Reference .............................................................. 13
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - FOR TEMPERATURE CONTROLLERS

PRODUCT DATA68-0040-04Immersion Wells and Compression FittingsFOR TEMPERATURE CONTROLLERSAPPLICATIONImmersion wells, compression fittings and element

Page 2 - SPECIFICATIONS

IMMERSION WELLS AND COMPRESSION FITTINGS68-0040—04 10Fig. 6. Mounting spring clip into well spud.Securing Bulb in Wells with SetscrewWells with a spud

Page 3 - 3 68-0040—04

IMMERSION WELLS AND COMPRESSION FITTINGS11 68-0040—04Fig. 11. Mounting sensing bulb and 311266D Bulb Holder in duct.NOTE: Dimensions shown in in. (mm)

Page 4 - 68-0040—04 4

IMMERSION WELLS AND COMPRESSION FITTINGS68-0040—04 12Bulb ShieldsA bulb mounted outdoors requires protection of a bulb shield.1. Expose the bulb to re

Page 5 - 5 68-0040—04

IMMERSION WELLS AND COMPRESSION FITTINGS13 68-0040—04CHECKOUTWhen installation is complete, check it as follows:1. Visually inspect the fittings in hy

Page 6 - 121371AA

IMMERSION WELLS AND COMPRESSION FITTINGS68-0040—04 14Table 8. Cross Reference .Old Part NumberDescriptionReplacement Part Number Notes121371G Immersio

Page 7 - GENERAL INFORMATION

IMMERSION WELLS AND COMPRESSION FITTINGS15 68-0040—04

Page 8 - INSTALLATION

Automation and Control SolutionsHoneywell International Inc. Honeywell Limited-Honeywell Limitée1985 Douglas Drive North 35 Dynamic DriveGolden Valley

Page 9 - Insert Sensing Bulb in Well

IMMERSION WELLS AND COMPRESSION FITTINGS68-0040—04 2ORDERING INFORMATIONWhen purchasing replacement and modernization products from your TRADELINE® wh

Page 10 - Bulb Holders

IMMERSION WELLS AND COMPRESSION FITTINGS3 68-0040—04Fig. 2. Immersion well dimensions and components.INSULATIONDEPTHINSULATIONDEPTHINSULATIONDEPTHINSU

Page 11 - Averaging Element Holders

IMMERSION WELLS AND COMPRESSION FITTINGS68-0040—04 4Table 1. Copper Immersion Wells.Table 2. Stainless Steel, Mild Steel, and Monel Immersion Wells.Sp

Page 12 - Strap-On Mounting

IMMERSION WELLS AND COMPRESSION FITTINGS5 68-0040—04Table 3. Capillary Compression Fittings.Material Spud Maximum Bulb Diameter Insulation Depth Capil

Page 13 - CROSS REFERENCE

IMMERSION WELLS AND COMPRESSION FITTINGS68-0040—04 6Table 5. Immersion Well Accessories .Description ApplicationSize in in. (except where noted) Part

Page 14 - 68-0040—04 14

IMMERSION WELLS AND COMPRESSION FITTINGS7 68-0040—04GENERAL INFORMATIONImmersion WellsAn immersion well consists of a metal tube, called the well shel

Page 15 - 15 68-0040—04

IMMERSION WELLS AND COMPRESSION FITTINGS68-0040—04 8threaded end of the spud can extend into the controlled medium. Consider this additional length wh

Page 16 - ® U.S. Registered Trademark

IMMERSION WELLS AND COMPRESSION FITTINGS9 68-0040—04WARNINGElectrical Shock Hazard or Equipment Damage Hazard.Can cause sever injury, death or short e