OWNER’S GUIDE
® U.S. Registered Trademark • Patents Pending
Copyright © 2004 Honeywell International Inc.
All Rights Reserved 69-1676—1
CT8775A,C
THE DIGITAL ROUND
NON-PROGRAMMABLE THERMOSTATS
CT8775A Heat Only Thermostat (20 to 30 Vac) and
CT8775C Heating-Cooling Thermostat (20 to 30 Vac)
Para obtener un documento con las instrucciones en español, por favor visite
nuestro sitio de web a: www.honeywell.com/yourhome.
Pour obtenir des notices techniques en français, veuillez consulter notre site web
www.honeywell.com/yourhome.
Contents
Step 1. Prepare for Installation .................................................................................................................................. 3
Step 2. Remove Old Thermostat ............................................................................................................................... 4
Step 3. Special Installations........................................................................................................................................ 4
Step 4. Label Thermostat Wires ................................................................................................................................. 5
Step 5. Separate Wallplate from Thermostat.............................................................................................................. 5
Step 6. Mount Decorator Cover Plate and Thermostat Wallplate............................................................................... 5
Step 7. Wire Wallplate Terminals................................................................................................................................ 8
Step 8. Customize the Thermostat ............................................................................................................................. 10
Step 9. Mount the Thermostat .................................................................................................................................... 11
Step 10. Set the System and Fan Switches ............................................................................................................... 12
Step 11. Operating the Thermostat............................................................................................................................. 13
Step 12. Check Operation of Heating and/or Cooling System ................................................................................... 13
If You Have A Problem ............................................................................................................................................... 15
Wiring Diagrams......................................................................................................................................................... 16
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - CT8775A,C

OWNER’S GUIDE® U.S. Registered Trademark • Patents PendingCopyright © 2004 Honeywell International Inc.All Rights Reserved 69-1676—1CT8775A,CTHE DIGI

Page 2 - MERCURY NOTICE

69-1676—1 10STEP 8. CUSTOMIZE THE THERMOSTATSet Fuel Switch (CT8775C Only)❑ To adjust the fuel switch, locate the switch labeled E/F on the wallplate

Page 3 - Tools for Installation

11 69-1676—1Table 3. Heat Cycle Rate.NOTE: The cooling cycle rate does not require adjustment and therefore cannot be changed.Fahrenheit/Celsius Indi

Page 4 - STEP 3. SPECIAL INSTALLATIONS

69-1676—1 12STEP 10. SET THE SYSTEM AND FAN SWITCHES (CT8775C ONLY)System Switch (see Fig. 5) ❑ Heat: The thermostat controls your heating system.❑ Of

Page 5 - AND THERMOSTAT WALLPLATE

13 69-1676—1STEP 11. OPERATING THE THERMOSTATNOTE: Batteries are not required because the temperature setting is held permanently in memory.Backlit Di

Page 6 - 69-1676—1 6

69-1676—1 14Cooling System (CT8775C Only)CAUTIONEquipment Damage Hazard.Can cause permanent damage to compressor or other equipment.Do not operate coo

Page 7 - 7 69-1676—1

15 69-1676—1IF YOU HAVE A PROBLEMTable 5. Solution Guide.Customer AssistancePlease read and follow the provided instructions for this thermostat. For

Page 8 - STRIP 5/16 IN. (8 MM)

69-1676—1 16Wiring Diagrams POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.WRHEATINGRELAY ORVALVE COILM1945011M19451H

Page 9

17 69-1676—1Notice:This thermostat is a Class B digital apparatus that complies with Canadian Radio Interference Regulations, CRC c. 1374.14COMPRESSOR

Page 10 - Set Heat Cycle Rate

69-1676—1 18Limited One-Year WarrantyHoneywell warrants this product to be free from defects in the workmanship or materials, under normal use and ser

Page 12 - 69-1676—1 12

69-1676—1 2Enjoy the benefits of The Digital RoundTM Thermostat by Honeywell.• Simple to use. Turn the dial to adjust the temperature setting.• Large

Page 13 - Display Temperature Setting

69-1676—1 J.S. Rev. 6-04 www.honeywell.com/yourhomeAutomation and Control SolutionsHoneywell International Inc. Honeywell Limited-Honeywell Limit

Page 14 - Equipment Damage Hazard

3 69-1676—1STEP 1. PREPARE FOR INSTALLATION❑ Check Table 1, the compatibility chart, to make sure the thermostat is compatible with your system. If yo

Page 15 - IF YOU HAVE A PROBLEM

69-1676—1 4STEP 2. REMOVE OLD THERMOSTAT❑ Test your heating and cooling systems to make sure they work properly. If either system does not work, conta

Page 16 - Wiring Diagrams

5 69-1676—1Replacing a thermostat that is connected to three wires on a warm air heating only systemIf you are replacing a thermostat that is connecte

Page 17 - CRC c. 1374

69-1676—1 6Mount Decorator Cover Plate (Optional) and Wallplate Directly to Wall❑ If using the decorator cover plate, pull the wires through the wirin

Page 18 - Limited One-Year Warranty

7 69-1676—1.Mount Decorator Cover Plate (Required) and Wallplate onto Electrical Box❑ Pull the wires through the wiring hole on the decorator cover pl

Page 19 - 19 69-1676—1

69-1676—1 8STEP 7. WIRE WALLPLATE TERMINALSIMPORTANTAll wiring must comply with local codes and ordinances. If unsure about household wiring procedure

Page 20

9 69-1676—1Table 2. Terminal Designations on Old and New Thermostats.NOTES:1. If wires were connected to both Rh and R terminals on the old thermostat