Honeywell 11255 User Manual

Browse online or download User Manual for Air purifiers Honeywell 11255. Honeywell 11255 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 136
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1

the filter and hvac store

Page 2 - 1-800-347-2220

10EZ Flow and EZ Flow IIDisposable Panel Air FiltersEZ Flow - Model 10155.xxxxxxEZFlow II - Model 10055.xxxxxxGeneralEZ Flow and EZ Flow II disposable

Page 3

100Standard Replaceable ModuleRoom Side Replaceable ModulePF-FPM-493-2424-RSR PF-FPM-493-2424-STD 99.99 23.87 23.63 360 1.68 659 0.86 PF-FPM-493-

Page 4

101FCP Carbon PleatActivated Carbon AdsorbersModels FCP*xxxxx (Where * indicates carbon type model of 201, 202, 204, 301,302, 304. See price book.) Th

Page 5

102FCP SelectionMedia Rated Flow InitialModel Number Nominal Size Actual Size Area (cfm) Resistance(inches) (inches) (sq. ft.) (inch w

Page 6 - Replacement Air Filter

103Improves IAQ through odor abatementand better particulate air filtrationMany strong odors in living spaces come frommaterials that are either stron

Page 7

104Sensory testingBody Odor Odor level testing was conducted in jars set up spe-cially for headspace odortesting. Sensory evalua-tion was run 20 hour

Page 8 - HD Industrial Grade

105Model C Disposable CarbonGas Phase Odor Control Filters50% Fill,models: C50-xxxxx 75% fill,models: C75-xxxxxxGeneralThe Model C Disposable

Page 9

1061.0 General1.1 Disposable carbon air filters shall be Model C asmanufactured by Flanders.2.0 Filter Construction2.1 Filters shall be constructed of

Page 10 - EZ Flow and EZ Flow II

107Superflow-VCDisposable Carbon AdsorberModels SFVC*-xxxxxx (Where * indicates carbon type: 201, 202,204, 205 or 209.See Price book.)Features and Ben

Page 11

Flanders - Foremost in Air FiltrationCorporate Headquarters, St. Petersburg, FL108Application ConsiderationsSuperflow-VC Adsorbers in HVAC airstreams

Page 12 - Pinch Frame

109Adsorber ProtectionParticulate contamination must be consideredwhen utilizing gas/vapor phase adsorbers. As aminimum, a Flanders prefilter with an

Page 13

Nominal Size (inch) Actual Size H x W x D (in) cfm @ 300 fpm Standard Carton Qty. Weight per Carton (lbs.)10x10x1 9-7/8 x 9-7/8 x 3/4 208 12 3.310x20x

Page 14 - Ring Panels, Links, Sleeves

110 110AdsorberModel Number(See Note 1)SFVC-242412SFVC-122412Nominal SizeH x W x D mm.(See Note 2)610 x 610 x 305305 x 610 x 305AdsorberModel Number(S

Page 15

111VaporcleanVapor Phase Air FilterModels VC-xxxx-xx-xx-xxxx-xx See price bookImportant Features• Maximized carbon surface area• Increased efficiency

Page 16 - Paintbooth Filtration

112Sample Model NumberVC 1501 16 01 2424 GDVaporclean Media type 24 ga Frame Style Size GasketVaporclean PerformanceThe pressure drop of the Vaporclea

Page 17 - SAR-1 Panels for Air Intake

Flanders - Foremost in Air FiltrationCorporate Headquarters, St. Petersburg, FL113GeneralHMZD carbon panels are available from 3/8” to 3”depths, and

Page 18 - FP3-Paint Arrestor

Flanders - Foremost in Air FiltrationCorporate Headquarters, St. Petersburg, FL114Pressure DropHMZD Panels can be incorporated into Vshaped configurat

Page 19 - 325Tand 425T-Cubes

Flanders - Foremost in Air FiltrationCorporate Headquarters, St. Petersburg, FL115Clean Air is Only a Block AwayFlanders, through innovative technolog

Page 20 - Series 225-Panel

116Guide Specifications1.0 General1.1 Molecular contamination control filters shall beFlanders High Mass and Zero Dust (HMZD) bond-ed carbonpanels. Pa

Page 21 - HD Poly-T/A

117TechsorbChemical Media for Gaseous Contaminant RemovalModels TS-*-B1 (Where * indicates chemical media designator. See price book.)General Applicat

Page 22 - Precision Pak

Flanders - Foremost in Air FiltrationCorporate Headquarters, St. Petersburg, FL118Notes1. Contaminant removal capacity is determined by passing a mois

Page 23 - PS125-Cube, PS125-Sock

GeneralFlanders Type 9 Holding Frames are used to con-struct built-up filter banks for upstream or down-stream access using ASHRAE rated filters. Typ

Page 24

12Pinch FrameDisposable Panel Air FiltersModel 11655.xxxxxxGeneralThe Flanders Pinch Frame disposable air filter pro-vides the user with a product of

Page 25 - Three-Stage

Flanders - Foremost in Air FiltrationCorporate Headquarters, St. Petersburg, FL120Fastener Selection ChartModel P FastenerModel C-2 and C-4 FastenerMo

Page 26 - Cut-to-Fit

121GeneralUni-Frames are designed for retaining air filtermedia pads in applications that require additionalmedia support. The frame is fabricated of

Page 27

122K-TracModular Filter Framing SystemSee model number development method on next page.Important Features• Provides substantial savings in field assem

Page 28 - Bulk Media and Pads

123Height CodeOverall Height (inch)Width CodeHeight Overall Face 15W 20W 25W 30W 35W 40W 45W 50W 55W 60W 65W 70WCode Height Velocity Overall Width (in

Page 29

124How the K-Trac Works• A= 24” x 24” face size filter. C = 24” x 12” face size filter.• Weight does not include filters. Add approximately 6 lbs

Page 30 - Auto Rolls

125Drawing Notes1. Framing members of extruded aluminum are factory-cut to exact length, pre-drilled and gasketed.2. One vertical support for the cent

Page 31

Flanders - Foremost in Air FiltrationCorporate Headquarters, St. Petersburg, FL126Perma FrameHard Ceiling Adaptor Framesfor Terminal ModulesModels HCF

Page 32 - Pre Pleat 40

127Guide Specifications1.0 General1.1 Sheet rock adaptor frame for ceiling mounted ter-minal modules shall be Perma Frame as manu-factured by Flanders

Page 33 - Principles of Operation

128Residential Air CleanerRefillsFor Space Gard® , Air Bear®, Honeywell® Air Cleaners*See model numbers in chart on next page.Media for high efficienc

Page 34 - Performance Data

129Efficiency by Particle SizeMicrons Efficiency0.35 16%0.62 28%0.84 38%1.14 47%1.88 68%3.46 75%4.69 71%6.20 69%8.37 66%Replacement for: FP Refill(s)

Page 35

13Nominal Size (inch) Actual Size H x W x D (inches) cfm @ 300 fpm Standard Carton Qty. Weight per Carton (lbs.)10x20x1 9-7/8 x 19-7/8 x 7/8 420 12 4

Page 36 - Pre Pleat HV

130Model 500ABAir Cleaner HousingModel 82855.052025GeneralThe Model 500AB air cleaner housing is designedfor use with the Model 500AB or 550AB cartrid

Page 37

131Versatile InstallationThe Model 500AB air cleaner housing can be installed in a variety of configurations; Highboy, Lowboy,Horizontal, Upflow or Ve

Page 38 - Pre Pleat 62R

132Airia 350Electronic Room Air CleanerImportant Features• Super quiet operation• Operates for pennies a day.• 4 stage filtration removes particles, o

Page 39 - Pre Pleat 62RM11

133GeneralThe Airia line of electronic air cleaners delivershigh, instantaneous filtering efficiency in a reliable,permanent package that is built to

Page 40

134SpecificationsAiria 1400 (16x25) Airia 2000 (20x25Rated Capacity 1400 CFM 2000 CFMElectrical Input 120 Vac, 1 Ph, 60 Hz 120 Vac, 1 Ph, 60 HzPower C

Page 41 - Pre Pleat Class 1

the filter and hvac store

Page 42

the filter and hvac store

Page 43 - Pre Pleat HT

Rugged, Heat-sealed,ConstructionFlanders Ring Panel andCube filters are made byheat sealing layers of syn-thetic filtering mediatogether over an inter

Page 44

15Series ST55-Polyester Panel Models ST55R-xxxx Ring Panel and ST55L-xxxx LinkTwo-ply 1” nominal media construction using a 1/2” nominal white poly-

Page 45

16Paintbooth FiltrationDowndraftPrep StationCrossdraftFlanders offers a wide variety of filtration products fordowndraft and crossdraft paintbooths an

Page 46

17SA600-G10 Diffusion Media for Air IntakeModels SA600-xxxFor downdrafts and prep stations. This filter pro-vides the highest level of protection aga

Page 47 - Superflow-V

18Series ST55 Panel for Air IntakeModels ST55R-xxxx and ST55L-xxxx-xxThe SERIES ST55 PANEL, made in the USA, is aneconomical choice for crossdraft bo

Page 48

19Series 331Y PAModels 331Y-xxx22 gram Fiberglass Paint Arrestor for use in allbooth types. Series 331Y is a high quality fiberglassmedia. Made with

Page 49 - Rigid-Air

PRODUCT CATALOG AMKT0103a Supersedes all previous catalogs.For fast, efficient service, contact us today at1-800-347-2220and look for us on the inter

Page 50 - Rigid-Air Box Type Filters

20Flanders - Foremost in Air FiltrationCorporate Headquarters, St. Petersburg, FL325T, which is 98% efficient, and the Series 425Twhich is 99% efficie

Page 51 - Rigid-Air Filters with Header

21port. The media overlaps the support, which pro-vides a gasketing effect reducing air bypass aroundthe filter. A tackifier is applied in between th

Page 52 - Gasketed Headers

22The filter media consists of 100% high bulk poly-ester fibers that are thermo-bonded with a fire retar-dant res” Support grilles of expanded metal

Page 53 - PrecisionCell

23PS125-BagModels125BAG-xxxxxxScrim-Back polyester media bags as prefilter.PS125 Bags are made from a single denier poly-ester media that contains a s

Page 54

24FP319A Two-stage and Three-stage Paint SystemsPaintbooth FiltrationPads: FP319AxxxxPAD, Ring Panels: FP319A2020PRK,Cubes: FP319Axxxx ,Bags: FP319Axx

Page 55

25123Avg123Avg123Avg3. Courtaulds yellow fuel tank coating (A)513X390 base + (B) 910X624 activator - Witha conventional air gun operating at 45 psi,wi

Page 56

26Service RollsFlanders Service Rolls air filtration media are man-ufactured in selected widths, prepared in rolllengths that make manageable roll siz

Page 57 - PrecisionCell HT

Typically, these are for Lennox type furnaces.(Lennox is a brand name. It is used here for systemidentification only.) Hammock rolls are 20 foot rolls

Page 58

28Wide selection of media typesFlanders offers a wide range of top quality air filtra-tion media available in bulk rolls and pads.Considering the uniq

Page 59 - PrecisionCell GT

29Flanders - Foremost in Air FiltrationCorporate Headquarters, St. Petersburg, FLthe filter and hvac store

Page 60

Dear Customer,As a global leader in the production of high quality air filtration prod-ucts, Flanders Corporation continues to develop new innovations

Page 61 - PrecisionCell II

30Auto RollsAutomatic Roll Filter ReplacementFlanders automatic roll replacements are furnished woundon spools or cores, ready for installation withou

Page 62

31Flanders - Foremost in Air FiltrationCorporate Headquarters, St. Petersburg, FLthe filter and hvac store

Page 63

32Important Features• Media maximizing v-pleat design• Expanded metal grid prevents media flutter while in operation• Diagonal and horizontal support

Page 64

33ExpandedMetalPleat BackingV-PleatDesignDoubleWallConstruction2-piece die-cut frameDiagonal gridsupports formaximumstrengthEfficientHigh-LoftMediaPri

Page 65 - EA Cartridge

34Capacities and DimensionsNotes:1. PD represents clean pressure drop in inches w.g. The recommended final pressure drop for all models is 1.0in. w.g.

Page 66

351.0 General1.1 Medium efficiency filters shall be Pre Pleat 40extended surface pleated filters as manufacturedby Flanders..1.2 Filter sizes and capa

Page 67

36Pre Pleat HVHigh Velocity and Gas Turbine PleatModels 85455.xxxxxxGeneralThe Pre Pleat HV pleated filter from Flanders isdesigned to operate in high

Page 68

DepthNominalDepth(inch)10 x 10 x 1 210 0.15 347 0.38 1.610 x 20 x 1 417 0.15 694 0.38 3.212 x 20 x 1 500 0.15 833 0.38 3.812 x 24 x 1 600 0.15 1000 0.

Page 69

38Pre Pleat 62RHigh Efficiency Pleated FiltersStandard Capacity: 85655.xxxxxxHigh Capacity: 85755.xxxxxxImportant Features• MERV 8 per ASHRAE Standard

Page 70 - Prefilters

re Pleat 62RM11 pleated panel filter enablesa significant upgrade in collection efficiencyover existing MERV 8 products at the sameresistance levels.

Page 71 - Precision Pak XDH

Disposable Air FiltersThe widest selection of disposablepanels you will find anywhere. Spunglass and synthetic media...all stan-dard sizes and almos

Page 72

401.0 General1.1 Air filters shall be Model Pre Pleat 62RM11 panelfilers, as manufactured by Flanders.2.0 Filter Construction2.1 Each filter shall co

Page 73 - Installation Considerations

41Pre Pleat Class 1UL 900 Class 1 Pleated FilterStandard Capacity: 85855.xxxxxxHigh Capacity: 85955.xxxxxxImportant Features• UL 900 Class 1 for flamm

Page 74

421.0 General1.1 Medium efficiency UL Class 1 fire rated pleatedfilters shall be Pre Pleat Class 1 as manufacturedby Flanders.1.2 Filter sizes and cap

Page 75 - Moisture/Oil Mist Separators

43Pre Pleat HTHigh Temperature Pleated FiltersStandard Capacity: 84555.xxxxxxHigh Capacity: 84655.xxxxxxUp to 400oFFlanders Pre Pleat HT filters are d

Page 76

441.0 General1.1 High Temperature pleated filters shall be PrePleat HT as manufactured by Flanders.1.2 Filter sizes and capacities shall be scheduled

Page 77 - Features

45E35Pleated Panel FiltersModels E35-xxxxxGeneralFlanders E35 extended surface pleated filters aredesigned to operate in most installations. Availabl

Page 78 - Standard KKM with Steel Frame

46124E35-10201E35-12201E35-12241E35-14201E35-14251E35-15201E35-16201E35-16251E35-18241E35-18251E35-20201E35-20241E35-20251E35-24241E35-10202E35-12202E

Page 79 - Alpha 95

47Flanders - Foremost in Air FiltrationCorporate Headquarters, St. Petersburg, FLGeneralSuperflow-V extended surface area low pressuredrop minipleat f

Page 80 - Pureform Media Pack

48Flanders - Foremost in Air FiltrationCorporate Headquarters, St. Petersburg, FLNominal Size 250 FPM 375 FPM 500 FPM 625 FPM 750 FPM Media Wt.Efficie

Page 81 - Holding Frames and Housings

49GeneralRigid-Air extended media surface rigid filters aredesigned for use in most commercial or industrialHVAC systems where medium to high efficien

Page 82

Medium & High Efficiency ExtendedSurface Type FiltersHuge line of “bag” filters in all of the most popularsizes and efficiencies, plus our new XDH

Page 83 - Alpha Cell

50Notes:1. PD represents clean pressure drop in inches w.g. Recommended final pressure drop for all models is 1.5 inches w.g.2. Operation down to zer

Page 84 - CFM Dimensions and Capacities

51Notes:1. PD represents clean pressure drop in inches w.g. Recommended final pressure drop for all models is 1.5 inches w.g.2. Operation down to z

Page 85

52Application GuidelinesRigid-Air filters may be used wherever job require-ments and available space will accommodate 6” or12” deep filters.Rigid-Air

Page 86

53GeneralPrecisionCell extended media separator type rigidfilters are designed for use in most commercial orindustrial HVAC systems where medium to hi

Page 87 - Alpha 2000

5412625 x 20 x 1225 x 16 x 1224 x 20 x 1224 x 18 x 1220 x 20 x 1220 x 16 x 1225 x 20 x 625 x 16 x 624 x 20 x 624 x 18 x 620 x 20 x 620 x 16 x 61750140

Page 88 - Separator or Separatorless

55PrecisionCell Single Header filters are rec-ommended for through-the-frame applica-tions. Install by loading the filters through theType 9 frame un

Page 89

56Application GuidelinesPrecisionCell filters may be used wherever jobrequirements dictate totally rigid filters and availablespace will allow only mi

Page 90

5757PrecisionCell HTHigh Temperature Rigid FiltersASHRAE 65% 86255.xxxxxxH ASHRAE 85% 88255.xxxxxxASHRAE 95% 89255.xxxxxxHGeneralPrecisionCell HT

Page 91 - Alpha HT

58OperatingNominal Size500 fpmMedia WeightEfficiencyLimit oFH x W x D (inch)RatingArea Eachcfm pd (sq. ft.) (lbs)75024 x 24 x 12 2000.35140 2660-65%24

Page 92

5959PrecisionCell GTGas Turbine Rigid FiltersASHRAE 65%z: PGT65xxxxxxxH ASHRAE 95%: PGT95xxxxxxxHGeneralThe PrecisionCell GT features heavy-duty con-

Page 93 - Superflow® 2K

Disposable Air Filters: PageHD Industrial Grade Heavy Duty Box Frame, Spun Glass or Synthetic Media . . . . . . . . . . . . . . . . .8EZ Flow and EZ

Page 94 - Superflow 2K Selection

6060Nominal Nominal 250 fpm 375 fpm 500 fpm 625 fpm Media WeightDepth Efficiency Size Area Each(inch) HxWxD cfm pd cfm pd cfm pd cfm pd (sq.ft.) (lb

Page 95 - Alpha Panel

61GeneralPrecisionCell II extended surface minipleat rigid fil-ters are a nominal four inches deep. They aredesigned for use in most commercial and i

Page 96

62ConstructionIn the Flanders tradition of state-of-the-art technology, PrecisionCell II filters are built with a minipleat mediapack to achieve a rug

Page 97

63PrefiltersPrefilters are always a wise choice for the protec-tion of minipleat filters no matter what the efficiencyor brand. The closely-spaced pl

Page 98

64Notes1. PD represents clean pressure drop in inches w.g. Recommended final pressure drop for all models is 1.5 inch w.g.2. Operation down to zero ai

Page 99 - Performance

65Important Features• Fully interchangeable with other manufac-turers’ hardware.• Heavy-duty fiberboard side panels.• Filters are UL 900 Class 2 lis

Page 100 - Guide Specifications

66Cfm CapacityPressure Drop(inch w.g.)Efficiency%ModelNumberActualHxWxD(inch) 1.0 General1.1 Filters shall be Model EA Series replacement fil-ters as

Page 101 - FCP Carbon Pleat

67GeneralPrecision Pak extended surface bag filters aredesigned for use in most commercial or industrialHVAC systems where medium to high efficiency f

Page 102 - FCP Selection

68Performance values stated may be averages typical of the products listed. Contact factory for actual performance testreports on specific products.Ho

Page 103 - PH Odor Control

1500750150075015007501500750150075015007501500750150075015007500.180.180.190.190.160.160.150.150.180.180.150.150.140.140.180.180.140.14200010002000100

Page 104 - Sensory testing

7HEPA and 95DOP FiltersAlpha 95 95% DOP Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79Alpha C

Page 105 - Model C

70Guide SpecificationsApplication GuidelinesPrecision Pak filters should be selected using 24” x12” face sizes. This allows for 12” increments inheig

Page 106 - Installation

71Important Features• INTREPIDTM by Kimberly-Clark• Extra high dust holding capacity• Dual stage gradient density electrostatic media• Low initial pre

Page 107 - Superflow-VC

72Nom.Width (inch)Nom.Height (inch)85% XDH Synthetic Media FiltersNominalDepth(inch)NumberofPockets241224122412241224122412241224122412 2412242424242

Page 108 - Model Number Development

7375% XDH Synthetic Media FiltersNominalDepth(inch)NumberofPocketsNom.Width (inch)NomHeight (inch)241224122412241224122412241224122412 2412242424242

Page 109 - Physical Data:

74Application GuidelinesPrecision Pak XDH filters should be selected using24” x 12” and 24” x 24” face sizes. This allows for12” increments in height

Page 110 - Superflow-VC Performance Data

75GeneralFlanders models MS and MSG MoistureSeparators are designed for use in air handling sys-tems requiring collection of water droplets or oilmist

Page 111 - Vaporclean

76Guide SpecificationsConstructionMoisture separators are constructed much like permanent metal washable filters. The nominal two inch thickmedia pac

Page 112 - Contaminant Matching

77GeneralFlanders Model KKM is a heavy duty, washable,aluminum media, all metal filter. KKM is suitable forall residential and commercial application

Page 113

781.0 General1.1 Washable air filters shall be KKM Air Filters as supplied by Flanders.2.0 Filter Construction2.1 Frame shall be galvanized steel with

Page 114 - Carbon Selection

79GeneralFlanders Alpha 95 Filters are designed for use inHVAC applications requiring cleaner air than is pos-sible with ASHRAE - rated filters, but w

Page 115 - Superior Performance

8HD Industrial GradeHeavy Duty Disposable Panel FiltersSpun Glass Media - Model 10255.xxxxxxSynthetic Media - Model 11255.xxxxxxGrille Sizes - Model 1

Page 116

80ConstructionFlanders manufactures both conventional SeparatorStyle and Pureform Separatorless 95 DOP Filters. Tomake a Separator Style filter, the

Page 117 - Techsorb

81Frame MaterialsAlpha 95 Filters are available in a variety of wood and metal frame materials such as particle board, plywood,galvanized steel and st

Page 118

82Guide Specifications1.0 General1.1 Alpha 95 filters shall be extended media (sepa-rator type) (Pureform separatorless type) filtersas manufactured b

Page 119

83Flanders - Foremost in Air FiltrationCorporate Headquarters, St. Petersburg, FLGeneralFlanders offers a complete line of Alpha Cell HEPAFilters in t

Page 120 - Fastener Selection Chart

84Flanders manufactures both conventionalSeparator Style and Pureform SeparatorlessHEPA Filters. To make a Separator Style filter,the media is folded

Page 121 - Uni-Frame

85Frame MaterialsAlphaCell Filters are available in a variety of wood and metal frame materials such as particle board, ply-wood, galvanized steel and

Page 122 - Construction

861.0 General1.1 Alpha Cell HEPA filters shall be extended media(separator type) (Pureform separatorless type) fil-ters as manufactured by Flanders.1.

Page 123

87High Capacity DesignThe Alpha 2000 High Capacity HEPA filter is avail-able in a nominal 12” depth configuration. It isdesigned for optimum performan

Page 124 - How the K-Trac Works

88Alpha 2000 HEPA Filter Dimensions and CapacitiesFilter Depth Filter Size and Frame Actual Face Size CFM Capacity at Clean Weight(inches) Depth Desig

Page 125

89Frame MaterialsAlpha 2000 Filters are available in a variety of wood and metal frame materials such as particle board, ply-wood, galvanized steel an

Page 126 - Perma Frame

9Standard Sizes Performance Data - HD Industrial GradeTypical initial (clean) pressure drop at nominal cfm is 0.07 in. w.g. for 1 in. filters and 0.10

Page 127 - Construction Details

901.0General1.1 Alpha Cell HEPA filters shall be extended media(separator type) (Pureform separatorless type)filters as manufactured by Flanders.1.2 F

Page 128 - Residential Air Cleaner

91GeneralFlanders manufactures metal-frame separator-styleHEPA filters for applications with high-temperaturerequirements up to 1,000°F (540°C) for ex

Page 129

92Guide Specifications1.0 General1.1 High temperature separator style HEPA filtersshall be Alpha HT models as manufactured byFlanders.1.2 Filter sizes

Page 130 - Model 500AB

93GeneralFlanders Superflow 2K is a V-bed HEPA filter(99.99% at 0.30 micrometer) specifically designedfor high airflow applications requiring HEPA eff

Page 131 - Versatile Installation

94Model Number Nominal Size Actual Size Media Area Rated FlowSF2K-(*)-G(location)-GG 24" x 24" x 12" 24" x 24" x 11-1/2"

Page 132 - Airia 350

95GeneralAlpha Panel Minipleat HEPA/ULPA filters are avail-able in two particle size efficiencies: 99.99% on 0.3µm and 99.99% on 0.12 µm. They are of

Page 133 - Airia 1000 and 2000

Flanders - Foremost in Air FiltrationCorporate Headquarters, St. Petersburg, FL96Guide Specifications1.0 General1.1 Minipleat HEPA/ULPA filters shall

Page 134 - Specifications

97GeneralFlanders Pureflo Terminal HEPA/ULPA FilterModules are lightweight low profile ducted units.The mini-pleat filter packs are designed to provid

Page 135

Clean Filter Resistance(“w.g)Clean Filter Filter Resistance(inchw.g)23-5/847-5/8PF†-493-2424-*PF†-493-2448-*PF†-591-2424-*PF†-591-2448-*23-5/847-5/8Ph

Page 136

9999Pureflo-FPMFan-Powered Terminal Filter ModulesStandard: PF-FPM*-xxxx-STD Room Side: PF-FPM*-xxxx-RSR(Where * is efficiency designator of 493

Comments to this Manuals