CM907 - User Guide7 day ProgrammableRoom ThermostatHoneywell Control Systems Ltd.Arlington Business Park,BracknellBerkshireRG12 1EBTechnical Help Desk
1011OPERATING THE CM907• PARTY Function The party function allows you to extend your heating program by a specied number of hours at
1011OPERATING THE CM907• DAY OFF FUNCTION The day off function allows you to temporarily run Sunday’s heating program for as many days as you desire
1213FINE TUNING THE CM907Changing the User ParametersThe user mode allows you to modify some basic settings of the thermostat to meet your personal pr
1213FINE TUNING THE CM907c. Now choose which one of the following parameters you would like to change: i) Change the time format ‘CLOCK SELECT’ s
1415How do I change the batteries on the CM907 when they run out?The thermostat constantly monitors the battery power level, which typically last for
1415FAQ’s & TROUBLESHOOTINGCan I use my CM907 to control my air-conditioning system?Yes, if your system has been set up correctly you can use your
1617FAQ’s & TROUBLESHOOTINGWhat other accessories can I buy that work with the CM907?1. Outside Temperature Sensor Accessory The Outside Tempera
1617Troubleshooting GuideSymptomCM907 has a blank LCD screenCM907 shows a ashing symbol on the LCD screenThe CM907’s LCD screen works but the heatin
1842010943-703 R1...an explanation for householdersA programmable room thermostat is both a programmer and a room thermostat. A programmer allows you
ContentsGETTING STARTED WITH THE CM907STEP 1: Installing the Batteries... 3STEP 2: Setting the Date and Time...
3This section shows you how to setup and run the thermostat in 3 simple steps:STEP 1: Installing the BatteriesNote: Please follow the instructions in
45STEP 2: Setting the Date and TimeTo set the Date and Time:a. Move the slider switch to the DATE position. ‘SET THE DAY’ will be displayed on the sc
45PROGRAMMING THE CM907 The Built-in Heating ProgramThe built-in heating program has 6 temperature level changes per day that can be set between 3.00
67PROGRAMMING THE CM907 b. To adjust the period start time press the or buttons and ‘TIME 1 OK?’ will be displayed. Holding the button down will c
67PROGRAMMING THE CM907 i. To exit the programming mode move the slider switch to the desired operating mode - AUTO, MAN or OFF. Note: To run the adj
89OPERATING THE CM907Choosing the Operating ModeThe thermostat can operate in three different modes: Automatic, Manual or Off. To set the operating mo
89OPERATING THE CM907• Temperature Override During normal operation (AUTO mode) the programmed temperature can be adjusted manually by pres