Honeywell VISIONPRO TH8320 User Manual Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
VisionPRO
TM
8000 Touchscreen Programmable Thermostat
68-0280—01 26
Manual Override of Fan Schedule (Table 8)
Auto—fan is automatically following the Fan schedule
(choices are Auto, On or Circulate).
On—overrides Fan schedule. Fan is continuously On.
Circ—overrides Fan schedule. Fan circulates randomly for
approximately 35% of time until the Auto position is selected.
a
Auto Override resumes the Fan Program in each schedule
period (Wake, Leave, Return and Sleep)
Operate VisionPRO™ 8000 Touchscreen
Set Time
1. Press Clock.
2. Use arrows to set current time.
3. Press Done key.
IMPORTANT
The current day of the week should already be set
correctly. If not, see Installer Setup to set the day.
Set Temperature Overrides
The thermostat has three temperature override options: Hold
Temperature Until, Permanent Hold and Vacation Hold.
HOLD TEMPERATURE UNTIL (TEMPORARY HOLD)
Holds temperature temporarily until the next scheduled period
time or until the time the user sets.
1. Press Up or Down arrow next to the temperature you
want to adjust. “Hold Temperature Until” time appears
on the screen. The Hold Temperature Until time defaults
to the start time of the next scheduled period.
NOTE: The Time Up and Down arrows are shown for
approximately seven seconds. Pressing on the
screen time (where the Hold Temperature Until time
is shown) allows the arrows to reappear.
Table 8. Manual Override of Fan Schedule Operation.
Fan
Setting
Fan
Schedule
Override
Setting
Call
for
Action
Energize
Terminal
Screen
Message
Under
Fan
Setting
Auto On Fan G On
Auto Circ None None Circ
Auto Circ Fan G Circ
On
Auto
a
——
On Circ None None Circ
On Circ Fan G Circ
Circ
Auto
a
——
Circ On Fan G On
DONE CANCEL