EAS System Connection
The following information should be used in conjunction with the manufacturer’s
documentation EAS system.
Checkpoint
®
EAS System Integration
Honeywell cables compatible with Checkpoint EAS systems include five
additional wires for device connection. Consult the table below for the
appropriate wire and terminal configuration.
Antenna and Interlock
†
Connection
Cable
(
MX-5S236-E-3 or MX-5S114-E-3)
Checkpoint Device
Wire Color Wire Gauge Connection Type
Solid Light Green Thin INTLK + Terminal
Interlock
†
Solid Black Thin INTLK - Terminal, GND
Red and White Thick Antenna + Terminal
Antenna
Black and White Thick Antenna - Terminal
No Insulation/Shield Antenna Shield
† Interlock functionality requires specific EAS device settings. Consult the
manufacturer’s EAS system documentation for the appropriate switch and timing
potentiometer settings.
Inside the Checkpoint device, two switch banks set the deactivation antenna
tuning. The recommended settings for the switch banks are shown below.
See page 39 for tag deactivation guidelines.
Switch Bank Settings
Settings of 0pF to 47pF are recommended to achieve a maximum
deactivation range.