Honeywell W8735B User Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
TELEPHONE ACCESS MODULE
69-1352 4
Wiring the Telephone
CAUTION
Incorrect Telephone Line Hookup Hazard.
Inability to call out can result in personal
injury or property damage.
Improper installation can result in blocked
phone lines and inability to make 911 and
other emergency-reporting phone calls.
Always connect the Telephone Access Module
first in line. When a monitored security system is
installed, connect the Telephone Access Module
second in line.
Observing this practice ensures that Telephone
Access Module drops off the line to allow priority
to the house telephone.
1.
Wire the telephone line from the telephone com-
pany to the Line in connections on the Telephone
Access Module.
IMPORTANT:
Wiring the Telephone Access Module first in line
(or second in line with a monitored security sys-
tem) ensures that when any house telephone is
used (such as for an emergency), the Tele-
phone Access Module drops off the line and
gives control priority to the house telephone.
2.
Wire the house telephones to the Phone out con-
nections (see Table 2) on the Telephone Access
Module.
3.
After the Telephone Access Module installation is
complete, be sure to verify that the emergency
telephone line disconnect is operating correctly.
a. Call the Telephone Access Module using an
outside line (installers use a cell phone).
b. While calling into the Telephone Access Mod-
ule, pick up a house telephone receiver. If you
get a dial tone after a few seconds and the
Telephone Access Module drops control of the
line, the Telephone Access Module is installed
correctly.
c. If you do not get a dial tone on the house tele-
phone, follow the wiring diagrams and rewire
the telephone connections. See Fig. 8 and 9.
IMPORTANT:
Do not leave the installation until the emergency
telephone line disconnect is operating correctly.
a
Connect to
either
Line in or use terminals Ln1 and Ln2.
b
Connect to
either
Phone out or use terminals Ph1 and Ph2.
Wiring Diagrams
See Fig. 7 through 9 for wiring diagrams.
Table 2. Terminal Designations.
W8735B Terminal Designations Function
1 To EnviraCom network terminal 1 (data).
2 To EnviraCom network terminal 2 (24 Vac).
3 To EnviraCom network terminal 3 (24 Vac).
Aux1 Auxiliary Input Connect to N.O. sensor contact.
Aux2 Auxiliary Input Connect to N.O. sensor contact.
Line in
a
RJ11 connector Connect to telephone line.
Phone out
b
RJ11 connector Connect to home telephones
Ln1 Line in - Connect to telephone line.
Ln2 Line in - Connect to telephone line.
Ph1 Phone out - Connect to home telephones.
Ph2 Phone out - Connect to home telephones.
Page view 3
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals

No comments