Page view 1
I
2
ROUTER
(NOT INCLUDED)
INTERNET
DSL/CABLE MODEM
(NOT INCLUDED)
2
1
32 4
LAN LANWAN
XG1OOO CONTROLLER
INSTALLATION CHECKLIST ///
XG1000 Controller and a Honeywell Bridge
6160 Alpha panel as a debugging tool
Confirm address 22 is open and configured as a keypad device.
Please note that if 22 is already is use, the existing keypad will need to be
moved to a different address
Remote account username and password
INSTALL & VALIDATE XG1000 CONTROLLER ///
1. Locate the customer’s external internet connection and the in-home router. Find one unused
LAN RJ-45 port on the router. Then, use an Ethernet cable to connect the LAN RJ45 port on
the XG1000 Controller to the unused LAN RJ45 port on the router.
2. Connect XG1000 Controller to power and verify the following:
The XG1000 ‘X’ power LED is lighted BLUE
If the power LED is not lighted, please re-check all power connections
(see Troubleshooting Section)
The XG1000 LAN/Link LED is lighted GREEN
If the LAN/Link LED does not light check the Ethernet connection and/or
try using a different Ethernet cable (see Troubleshooting Section)
3. Wait up to 3 minutes for the XG1000 Controller to initialize.
4. Check and confirm LED marked ‘REM is solid GREEN (REM LED is the health indicator
for remote access).
POWER
INDICATOR
LAN LINK
REMOTE
CONNECTIVITY
ACT
STAT
REM
DEV
ACT
LINK
LAN
CONTROL TERMINAL STRIP
AUX.
4
AUX.
+
5
DATA
IN
6
DATA
OUT
7
HONEYWELL
BRIDGE
SAFEWATCH PRO 3000
BRIDGE RED WIRE
BRIDGE YEL WIRE
BRIDGE GRN WIRE
TO KEYPAD YEL WIRE
TO KEYPAD GRN WIRE
TO KEYPAD BLK WIRE
TO KEYPAD RED WIRE
BRIDGE BLK WIRE
HONEYWELL BRIDGE INSTALLATION PROCEDURE ///
1. Connect the Honeywell Bridge to the Honeywell Panel (or the keypad if possible)
The Bridge connects just like an additional keypad (SafeWatch Pro 3000 terminals noted).
Please power down the Honeywell Panel prior to beginning this process:
Black wire to Pin 4
Red wire to Pin 5
Green wire to Pin 6
Yellow wire to Pin 7
NOTE: The existing keypad will remain connected. Mount the Bridge device near the alarm panel away
from large metal objects. If necessary, you can extend the length of the wire using four conductor cable
and wire nuts. For best results the bridge device should be mounted as high as possible, preferably at
least 6 feet above the floor.
2. Re-connect power to the Honeywell Panel.
3. The LED on the Honeywell Bridge should light up and display RED If the LED does not light up,
the Bridge is not receiving power, please check all connections (see Troubleshooting Section).
If the LED changes from solid GREEN to solid RED within the first 60 seconds after applying power,
and remains solid RED, the Controller and the Bridge may be having difficulty communicating.
Please perform the Range Test described in the Troubleshooting Section of this manual.
4. Go to existing alarm keypad. Disarm the alarm system, establish access to alarm system
via the “Installer Code (may need to re-power unit and use ‘#*to set an installer code).
5. Connect a 6160 ALPHA KEYPAD if existing keypad is not alpha. From the keypad enable
the keypad address 22 in the alarm panel for use by the Honeywell Bridge (for the SafeWatch
Pro 3000, enter [ 1, 0 ]’ in location ‘*195).