VisionPRO
TM
8000 Touchscreen Programmable Thermostat
39 68-0280—01
Heat pump puts out cool air in
the heat mode and warm air in
the cool mode.
Changeover Valve (Installer Setup
Number 0190) is not configured to
match the changeover required by the
installed heat pump.
Set Changeover Valve (Installer Setup
Number 0190) to match the changeover
required by the installed heat pump.
Both the heating and cooling
equipment are running at the
same time.
The heating equipment is not a heat
pump but the System Type (Installer
Setup Number 0170) is set to Heat
Pump.
Set System Type (Installer Setup Number
0170) to match the installed heating and/or
cooling equipment.
Heating and cooling wires are shorted
together.
Separate the shorted heating and cooling
wires.
Heating equipment is running
in the cool mode.
Heating equipment is not a heat pump
but System Type (Installer Setup
Number 0170) is set to Heat Pump.
Set System Type (Installer Setup Number
0170) to match the installed heating and/or
cooling equipment.
Heating equipment does not
turn off and heat temperature
setting is set below room
temperature (Heat On is not in
the display).
Heating equipment is not a heat pump
but System Type (Installer Setup
Number 0170) is set to Heat Pump.
Set System Type (Installer Setup Number
0170) to match the installed heating and/or
cooling equipment.
Cannot set the system setting
to Heat.
System Type (Installer Setup Number
0170) is set to Cool Only.
Set System Type (Installer Setup Number
0170) to match the installed heating and/or
cooling equipment.
Cannot set the system setting
to Cool.
System Type (Installer Setup Number
0170) is set to Heat Only or Heat Only
with Fan.
Set System Type (Installer Setup Number
0170) to match the installed heating and/or
cooling equipment.
Heat On is not in the display. System setting is not set to Heat and/or
temperature setting is not set above
room temperature.
Set the system setting to Heat and set the
temperature setting above the room
temperature.
Cool On is not in the display. System setting is not set to Cool and/or
the temperature setting is not set below
room temperature.
Set the system setting to Cool and set the
temperature setting below the room
temperature.
Wait is in the display. Compressor minimum off timer is
active.
Wait up to five minutes for the cooling or
heating (heat pump) equipment to turn on.
“Screen Locked” appears on
the screen and all or some of
the keys do not respond.
The keypad is fully or partially locked. Check Installer Setup Number 0670 to
change keypad locked options.